Bio-chemical Lab

Elite

Wireless Electrochemical Workstation

Redefining electrochemical analysis with a palm-sized, wireless potentiostat. Lab-grade precision for biosensing and materials research, anywhere.

Elite EDC Device
Overview

Precision Meets
Portability.

Gone are the days of bulky, rack-mounted potentiostats tethered to desktop computers. The Elite EDC series compresses high-fidelity electrochemical measurement technology into a compact, wireless module.

Whether inside a glovebox, an incubator, or out in the field, Elite delivers reliable data on Cyclic Voltammetry (CV), I-V curves, and Amperometry directly to your browser.

Lab Environment

Uncompromised Performance

Compact and lightweight design for easy portability

Compact and lightweight design for easy portability

Wireless data transmission in real-time

Wireless data transmission in real-time

Effortless data acquisition and streamlined management

Effortless data acquisition and streamlined management

Interface

Effortless Control.
Real-time Visualization.

The Elite system is controlled via a modern, responsive web interface hosted directly on the Controller.

  • Real-time plotting of I-V curves and CV cycles
  • Instant parameter adjustment during live experiments
  • One-click data export to CSV for Excel/Matlab
  • Visual identification of connected devices via LED
Request Demo
Status: Running...
Fields of Study

Research Applications

Material Science

Biosensor Development

Characterize novel sensing materials (e.g., Graphene, Carbon Nanotubes) with precise CV scans.

Diagnostics

Point-of-Care Testing (POCT)

Develop rapid diagnostic platforms for detecting glucose, lactate, or specific biomarkers.

Environment

Environmental Monitoring

Field-deployable solution for detecting heavy metals or pollutants in water sources.

Energy

Energy Storage

Basic characterization of micro-batteries and supercapacitors.

Wearables

Wearable Bio-electronics

Testing flexible electrodes for sweat analysis or non-invasive health monitoring.

Academia

Education

Safe, easy-to-use platform for teaching electrochemistry fundamentals in university labs.

Technical Specifications

Feature

EDC-03

EDC-03

EIS-01

EIS-01

EIS-mini

EIS-mini

TRIG-01

TRIG-01
Voltage Output±5.0 V
(Res.: 0.6 mV)
±2.0 V
(Res.: 0.1 mV)
±2.0 V
(Res.: 0.1 mV)
Time res.: ~ 50 ms
Voltage Input±5.0 V
(Res.: 0.6 mV)
±2.0 V
(Res.: 0.1 mV)
±2.0 V
(Res.: 0.1 mV)
Max. current regulation range: 200.0 mA/ch. and total 800.0 mA
Current Input±15.0 mA
(Res.: 1 nA)
±3.0 mA
(Res.: 1 nA)
±3.0 mA
(Res.: 1 nA)
Frequency15 mHz ~ 200 kHz15 mHz ~ 200 kHz
Sample rate (sps)0.01 - 1000.01 - 1000.01 - 100
Size (L×W×H)60 x 60 x 19 mm60 x 60 x 19 mm20 x 30 x 8 mmØ70 x 20 mm
Weight~ 60 g~ 60 g~ 50 g
FunctionsIV-curve, Constant Current, V, I, R-t Monitoring, Voltammetry (OCP, CV, LSV, CA, CP, DPV), PulseEIS, CF, CV, CA, CP, LSV, DPV, OCP, V-I-R MonitoringEIS, CF, CV, CA, CP, LSV, DPV, OCP, V-I-R Monitoring2 channels of isolated switches
2 channels capable of 5V output
4 channels of current regulators
2 channels of trigger input
* Specifications subject to change without notice.